The Toshiba RAS-22N3KV2-A is a 6.0 kW inverter split-system air conditioner available in Australia and South-East Asia. Service manual available on ManualsLib (manual 833319), with detailed check code tables from page 68.

Check CodeFault Description
0CTA sensor open or short circuit — indoor air temperature sensor fault
0DTC sensor open or short circuit — indoor heat exchanger temperature sensor fault
04Indoor to outdoor unit communication error — compressor thermostat signal lost
11Indoor fan motor failure — motor stopped or speed not reached
1AOutdoor fan motor failure — outdoor fan stopped or speed not reached
1CCompressor drive circuit fault — inverter circuit failure
1ECompressor high discharge temperature — TD sensor reads above 120 degrees C