Toshiba RAS-10N3KV2-A Air Conditioner Error Codes
RAS-10N3KV2-A Error Code Reference
Section titled “RAS-10N3KV2-A Error Code Reference”The Toshiba RAS-10N3KV2-A is a 2.5 kW (9,000 BTU) inverter split-system air conditioner. The RAS-10N3KV2-A (indoor) pairs with the RAS-10N3AV2-A (outdoor). Sold in Australia and South-East Asia. Service manual available on ManualsLib (manual 3826338).
| Check Code | Fault Description |
|---|---|
| 0C | TA sensor open or short circuit — indoor air temperature sensor fault |
| 0D | TC sensor open or short circuit — indoor heat exchanger temperature sensor fault |
| 04 | Indoor to outdoor unit communication error — compressor thermostat signal lost |
| 11 | Indoor fan motor failure — motor stopped or speed not reached |
| 1A | Outdoor fan motor failure — outdoor fan stopped or speed not reached |
| 1C | Compressor drive circuit fault — inverter circuit failure |
| 1E | Compressor high discharge temperature — TD sensor reads above 120 degrees C |