Skip to content

What Does dH Error Mean on LG LRSXS26366S?

Error dH on LG LRSXS26366S: Defrost heater failure — freezer defrost sensor did not reach 40°F within 80 min. Follow the troubleshooting steps below to diagnose and fix this refrigerator issue. The dH error code on your LG LRSXS26366S refrigerator indicates the defrost heater failed to raise the defrost sensor temperature to at least 40°F (5°C) within 80 minutes of the start of a defrost cycle. The control board monitors this temperature rise to confirm the heater is melting the frost on the evaporator coils. A failed defrost heater or a tripped defrost thermostat are the most common causes. ## What Does dH Mean? Every LG refrigerator including the LRSXS26366S performs automatic defrost cycles several times per day. During each cycle, the main control board powers the defrost heater — a resistive heating element wrapped around the evaporator coil. The heater melts accumulated frost and the melt water drains through the drain pan. The defrost sensor monitors the temperature rise. When the defrost sensor does not reach 40°F within 80 minutes of the heater being activated, the control board concludes the heater is not working and logs dH. The heater itself may have an open circuit, or the defrost thermostat (also called a cutoff or safety thermostat) may have tripped and opened the circuit before the sensor reached the threshold temperature. The dH error leads to progressive frost accumulation on the evaporator coil. If uncorrected, this eventually blocks airflow completely and triggers FF or rF fan errors as the growing ice mass contacts the fan blades. ## Possible Causes 1. Failed defrost heater with an open circuit — the heating element no longer generates heat when powered 2. Tripped or failed defrost thermostat that opened the defrost circuit before the sensor reached the required temperature 3. Failed defrost sensor providing incorrect low temperature readings that prevent the control board from recognizing successful defrost 4. Loose wiring connection in the defrost circuit between the heater, thermostat, and control board 5. Failed main control board defrost relay not supplying power to the defrost heater ## Troubleshooting Steps | Step | Action | Expected Result | |------|--------|-----------------| | 1 | Unplug the LRSXS26366S and allow the freezer to fully defrost manually for 8 to 24 hours with the door open to clear any existing ice before diagnosing the defrost circuit | Freezer is fully defrosted and accessible for testing | | 2 | Locate the defrost heater — it is wrapped around or mounted adjacent to the evaporator coil behind the back panel of the freezer; remove the freezer back panel (typically 4 to 6 screws) to access the heater | Defrost heater is accessible | | 3 | Disconnect the heater wiring and measure resistance across the heater terminals with a multimeter; a working heater typically reads 20 to 50 ohms depending on the model; a reading of OL (open circuit) confirms a failed heater requiring replacement | Heater resistance is measured — OL confirms failure | | 4 | Test the defrost thermostat by measuring continuity across its terminals at room temperature — a working thermostat shows continuity (closed) at room temperature; no continuity (open) at room temperature indicates it has tripped or failed | Defrost thermostat shows correct continuity at room temperature | | 5 | Test the defrost sensor resistance — at approximately 32°F (0°C) the sensor should read approximately 5,000 to 8,000 ohms depending on model; a reading far outside this range indicates sensor failure | Defrost sensor resistance is within specification | | 6 | Replace any component that tested failed; reconnect all wiring and restore power; monitor the freezer for recurrence of dH or fan errors | dH does not return after replacing the defective defrost component | The defrost heater operates at 120V AC. Disconnect all power before testing or replacing the defrost heater, thermostat, or sensor. If refrigerant tubing is visible near the evaporator coil, do not apply force — puncturing a refrigerant tube requires professional evacuation and recharge. ## When to Call a Technician Contact LG authorized service if: - All defrost circuit components tested good but dH persists — the main control board defrost relay has failed

  • The evaporator coil is covered in a solid block of ice that cannot be safely cleared without risk of damaging the tubing
  • The dH error is recurring frequently, indicating a systemic defrost system failure requiring professional diagnosis Professional repair costs for dH issues typically range from $100 to $320 depending on the specific component and your service region. ## Frequently Asked Questions ### Does dH always mean the defrost heater is broken? Not necessarily. While a failed defrost heater is the most common cause of dH, a tripped defrost thermostat can produce the same error. The thermostat opens the circuit when it detects excessive temperature, and if it has failed in the open position, the heater never receives power. Test both components before ordering replacement parts. Also test the defrost sensor, as a falsely low sensor reading can trigger dH even when the heater is working.

How long does LG refrigerator defrost cycle run? LG refrigerators typically run automatic defrost cycles every 6 to 8 hours of compressor operation. Each defrost cycle lasts up to 80 minutes. The dH error triggers when the sensor does not reach 40°F within that 80-minute window. Normal cycles typically complete successfully within 20 to 40 minutes. If the heater is undersized or partially failing, it may take longer and eventually fail to reach the threshold.

Section titled “How long does LG refrigerator defrost cycle run? LG refrigerators typically run automatic defrost cycles every 6 to 8 hours of compressor operation. Each defrost cycle lasts up to 80 minutes. The dH error triggers when the sensor does not reach 40°F within that 80-minute window. Normal cycles typically complete successfully within 20 to 40 minutes. If the heater is undersized or partially failing, it may take longer and eventually fail to reach the threshold.”

Can I reset the dH error code? You can reset the display by unplugging the refrigerator for 5 minutes. However, the dH error will return at the next defrost cycle attempt if the underlying heater, thermostat, or sensor fault has not been repaired. A reset clears the display only — it does not fix the defrost circuit.

Section titled “Can I reset the dH error code? You can reset the display by unplugging the refrigerator for 5 minutes. However, the dH error will return at the next defrost cycle attempt if the underlying heater, thermostat, or sensor fault has not been repaired. A reset clears the display only — it does not fix the defrost circuit.”

Will dH damage my LG refrigerator permanently? If dH is ignored, frost will accumulate progressively on the evaporator coil until it covers the coil completely and blocks all airflow. This eventually results in the fan errors FF and rF, and ultimately in complete loss of cooling in both compartments. The evaporator coil itself will not be permanently damaged by frost accumulation, but extended operation in this state can shorten the compressor lifespan. Reference: LG official support documentation (lg.com/us/support) and authorized service guides ### Is it safe to keep using my LG LRSXS26366S with error dH? If error dH does not indicate an immediate safety hazard such as a gas leak, electrical short, or water flooding, you can continue limited use while monitoring the appliance. However, running the refrigerator with an active error code increases the risk of further damage. Address the underlying issue as soon as possible. For high-severity errors, disconnect the appliance and contact a qualified technician. ### How much does it cost to fix error dH on a LG LRSXS26366S? Repair costs for error dH on the LG LRSXS26366S refrigerator depend on the root cause. DIY fixes such as cleaning filters, resetting the unit, or reconnecting loose wires cost nothing beyond basic tools. If a component replacement is needed, parts and labor from a certified technician are the main expenses. Contact a LG-authorized service provider for an accurate estimate based on your specific situation. ### What does error code dH mean on a LG refrigerator? Error code dH on LG refrigerator models indicates Defrost heater failure — freezer defrost sensor did not reach 40°F within 80 minutes of defrost cycl. This error is detected by the appliance’s internal diagnostic system and displayed to alert the user that attention is needed. Refer to the troubleshooting steps above for guidance on resolving this issue.

Section titled “Will dH damage my LG refrigerator permanently? If dH is ignored, frost will accumulate progressively on the evaporator coil until it covers the coil completely and blocks all airflow. This eventually results in the fan errors FF and rF, and ultimately in complete loss of cooling in both compartments. The evaporator coil itself will not be permanently damaged by frost accumulation, but extended operation in this state can shorten the compressor lifespan. Reference: LG official support documentation (lg.com/us/support) and authorized service guides ### Is it safe to keep using my LG LRSXS26366S with error dH? If error dH does not indicate an immediate safety hazard such as a gas leak, electrical short, or water flooding, you can continue limited use while monitoring the appliance. However, running the refrigerator with an active error code increases the risk of further damage. Address the underlying issue as soon as possible. For high-severity errors, disconnect the appliance and contact a qualified technician. ### How much does it cost to fix error dH on a LG LRSXS26366S? Repair costs for error dH on the LG LRSXS26366S refrigerator depend on the root cause. DIY fixes such as cleaning filters, resetting the unit, or reconnecting loose wires cost nothing beyond basic tools. If a component replacement is needed, parts and labor from a certified technician are the main expenses. Contact a LG-authorized service provider for an accurate estimate based on your specific situation. ### What does error code dH mean on a LG refrigerator? Error code dH on LG refrigerator models indicates Defrost heater failure — freezer defrost sensor did not reach 40°F within 80 minutes of defrost cycl. This error is detected by the appliance’s internal diagnostic system and displayed to alert the user that attention is needed. Refer to the troubleshooting steps above for guidance on resolving this issue.”