Model Overview
Section titled “Model Overview”The Haier GE GFW510SCN0 is a high-efficiency front-load washer designed for residential use, offering advanced features like inverter motor technology and precise water level control. This model includes comprehensive self-diagnostic capabilities with a detailed error code system to simplify troubleshooting.
Error Codes
Section titled “Error Codes”| Error Code | Description |
|---|---|
| 0 | No Faults; Displayed in Service Mode only when there are no faults to display |
| 1 | Lock Monitor; This fault is set if the motor shaft speed exceeds 45 RPM for 5 seconds |
| 2 | Door Monitor; Control did not get Door closed signal from switch while motor was running |
| 8 | Pressure Sensor Loss; Determines if appropriate pressure changes are seen during fill |
| 9 | Door Switch Redundancy; Three cycles have been completed without any door opening events |
| 18 | Drain Pump Clearing Algorithm Failed; Pressure sensor indicates water in the tub after drain |
| 19 | UI State Timeout; This will happen if a cycle is paused for greater than 24 hours |
| 20 | Critical Flood Level by Gallons; Water volume into the tub exceeded 41 gallons at any time |
| 22 | Out of Balance (OOB) During Dry Load Sense; Large wet/OOB load being washed |
| 24 | Door Logic Failure; Door lock failure. This fault is set if the system perceives inconsistent door states |
| 25 | Pressure Sensor Dropout, Pressure Sensor Continuous Gallons Monitor; This fault is set if pressure sensor readings are inconsistent |
| 26 | Out of Balance (OOB) Ended Final Spin; Washer detected an out of balance load and aborted spin |
| 27 | IMP Overheated; Inverter over temperature (> 221°F) for 5 seconds |
| 29 | Drive System Self-Check Fault; MCU failed self-check |
| 30 | Main Board Over Voltage; When connected to power, voltage is higher than 160 VAC |
| 31 | Main Board Self Check Failed; MCU failed self-check |
| 35 | Accelerometer Faults; Any of these faults can be set if the accelerometer fails self-test |
| 57 | Door Lock Fault Water Above Door by Pressure; This fault is set when door is unlocked with water above door level |
| 58 | ADC Health Check Fault; After drain control should go to idle End Cycle ADC Health Check Fault |
| 62 | Inverter Power And Door Lock Monitor; The fault is set when the system request inverter power but door is not locked |
| 70 | Inverter Volt/ Hertz Start Up; Inverter volt hertz star up 135 is set five times in a row |
| 77 | See Fault Code 32 |
| 78 | Board Communication API Mismatch; The Main Board detects that it doesn’t have the correct API version |
| 85 | Voltage Detected by MC; Voltage detected by MC is outside acceptable window |
Common Issues
Section titled “Common Issues”- Excessive vibration during spin – Often caused by an unbalanced load. Redistribute clothes evenly.
- Drain pump failures (Error 18) – Check for clogs in the drain hose or pump filter.
- Door lock faults (Error 24, 57) – Inspect door latch mechanism and ensure proper alignment.
- Overheating inverter (Error 27) – Verify proper ventilation around the washer and avoid overloading.
- Pressure sensor errors (Error 8, 25) – Ensure water supply pressure is within range and inspect sensor connections.
Technical Specifications
Section titled “Technical Specifications”- Type: Front-load washer
- Capacity: 4.5 cu. ft.
- Motor: Inverter-driven direct drive
- Voltage: 120V AC, 60Hz
- Water Levels: Multiple precision-controlled levels
- Cycle Options: Includes heavy-duty, quick wash, and delicate cycles
- Diagnostics: Self-diagnostic error code system
- Flood Protection: Automatic shutoff if water exceeds 41 gallons (Error 20)
- Compliance: Meets ENERGY STAR® efficiency standards