Skip to content

Haier GE GDF450P R0 Series Dishwasher

The Haier GE GDF450P R0 Series is a built-in dishwasher designed for residential use, featuring multiple wash cycles and energy-efficient operation. This model includes advanced diagnostics with error code displays for troubleshooting common issues. Its compact design accommodates standard place settings while maintaining quiet performance.

Error CodeDescription
2Adc or HrF; Internal Board Failure; Replace machine control board. Power cycle t
FTDFailure to Drain; Check for clog in air gap/disposer, drain hoses, and drain
H20Water Supply Failure; Verify the water supply line is connected properly, the
ACFHigh Supply Voltage; Check the supply voltage. Supply voltage is greater than
PRSPressure Sensor Failure; Verify pressure sensor harness has continuity. Unplu
F32Water Level Sensor Invalid; Check to see if pressure sensor is plugged in. If so
F36CSM Tripped (CSM Lock Out); Entering Circulate Test or Heater Test will Reset th
F60Heater Relay Stuck On Fault; Clear faults and cycle power to unit. If fault reoc
F61CSM Check Failed; Cycle power and start cycle to clear fault. If fault does not
F63Flood Condition Fault; The pressure sensor has detected the water level above th
F86No Fill Failure; Check water valve to see if a water source is hooked up to the
F96Ignore Fault; Ignore fault.
F154Door Latch Diagnostic; Replace machine control board.
F155Tactile Key Stuck; Check button operation, each button should “click”. Check for
F158Overvoltage; An overvoltage condition has been detected by the control. Check in
  1. Drainage Problems: Often caused by clogs in the drain hose or air gap. Inspect for debris and ensure proper installation.
  2. Water Supply Failures: Check for kinks in the inlet hose or low water pressure from the household supply.
  3. Control Board Errors: Persistent internal faults may require board replacement or professional servicing.
  4. Pressure Sensor Issues: Faulty readings lead to incorrect water level detection; verify sensor connections.
  5. Heater Malfunctions: Relay faults or sensor errors can disrupt heating; power cycling may temporarily resolve.
  • Type: Built-in dishwasher
  • Capacity: Standard place settings (varies by configuration)
  • Wash Cycles: Normal, Heavy, Rinse, Eco, and more
  • Voltage: 120V AC (check local requirements)
  • Water Pressure Requirement: 20-120 psi
  • Noise Level: ≤50 dB (varies by cycle)
  • Dimensions: Standard 24-inch width (exact measurements vary)
  • Diagnostics: LED error code display
  • Compatibility: Standard household plumbing connections